Room Code OR-DIG-I
Net Room Area Briefed 55
Hours of Operation 24 Hours
Occupancy 1 patient; 5 - 12 staff
Description / Special Requirements The Operating Room - Digital provides a fully digital integrated aseptic environment in which to carry out surgical procedures under local, regional or general anaesthetic.The digital operating room will include ceiling pendant systems, operating theatre imaging equipment and video monitoring equipment. The Operating Room - Digital may be used for a range of surgical procedures including specialty surgery. The Operating Room will have direct access to a Scrub-up Room, exit bay and sterile stock/set-up area. Cardiac Protected electrical area Special Air Conditioning - HEPA filtration Additional Design Considerations: - Associated rooms and layout to be considered in total - Square room shape preferable - 'Laser in Use' warning lights may be required outside exit doors to room if laser is to be used - External windows are desirable - double glazed with with integral Venetian blinds
Amendment 24.10.2010 - First Draft 29.05.2014 - General amendments to Fabric, FF, FE and Services
ID Fabric Material Finish Specification Selection Remarks
5010 Ceiling Plasterboard Paint, washable Flush set, suspended 3000mm min height AFFL
6015 Cornice Plasterboard Paint Flush coved between wall & ceiling
7010 Observation Glass Clear Through door/s with cover, (sliding)
9004 Doors Solid Core/ Glass Paint Single leaf, observation panel 920mm clear opening to scrub room
9225 Doors Solid Core/ Glass Paint Double leaf, observation panel 1500mm clear opening to patient entry/exit
1000 Floor finish Vinyl Standard slip resistant Seamless, coved
2000 Skirting Vinyl Prefinished Floor vinyl coved, 150mmH
9004 Doors Solid Core/ Glass Paint Single leaf, observation panel 1100mm clear opening to sterile stock/ clean-up rooms
2513 Door protection Composite Prefinished PVC insert Protection plate to 900 AFFL
2514 Door Protection Composite Prefinished PVC insert To door frame
3052 Wall finish Vinyl Prefinished Wall vinyl to 1500mm AFFL
ID Description Category Group Qty Selection / Remarks
150 Air flowmeter Furniture/ Fitting 3 2 to services on pendants
300 Trolley: anaesthetic Furniture/ Fitting 3 1
1102 Bench: resinate, mobile Furniture/ Fitting 3 1 Documentation station: computers, write-up; optional
1440 Bowl stand: single Furniture/ Fitting 3 2
1580 Chair: anaesthetist Furniture/ Fitting 3 1
6152 Dispenser: disposable glove Furniture/ Fitting 2 1
8390 Trolley: gowns Furniture/ Fitting 3 1
10200 Trolley: instrument Furniture/ Fitting 3 3
11100 IV stand: mobile Furniture/ Fitting 3 2
11500 Kickbucket & stand Furniture/ Fitting 3 2
12300 Linen carrier: dirty, single Furniture/ Fitting 3 1
13500 Table: mayo Furniture/ Fitting 3 1
15100 Bracket: monitor Furniture/ Fitting 3 1 optional, for monitor screen if required
16250 Oxygen flowmeter Furniture/ Fitting 3 4 to services on pendants
19060 Safe: dangerous drugs, small Furniture/ Fitting 1 1 optional
21730 Stool: operating, mobile Furniture/ Fitting 3 2
21950 Suction adapter Furniture/ Fitting 3 4 to services on pendants
22000 Suction bottle Furniture/ Fitting 3 4 in mobile carrier
22050 Suction bottle carrier Furniture/ Fitting 3 1
24400 Whiteboard Furniture/ Fitting 2 1 optional
ID Description Grp Qty Ele Data CdW HtW WmW Tap Dns Gas Selection / Remarks
2777 Monitor - LCD flat sceen 3 1 yes yes ___ ___ ___ ___ ___ ___ wall mounted, to Documentation station
5133 Anaesthetic machine + monitor 3 1 yes opt ___ ___ ___ ___ ___ ___
5135 Services pendant: 1 arm, height adj 1 1 yes yes ___ ___ ___ ___ ___ ___ 1x Anaesthetic services arm
5137 Light: operating, 2 arm, light/ monitor: LCD flat screen 2 2 yes yes ___ ___ ___ ___ ___ ___ with camera attachment to one (optional)
5138 Laparoscopic surgical equipment 3 1 yes yes ___ ___ ___ ___ ___ ___ Insufflator, light source, camera controller/ processor, video monitor; TBC by project
5136 Camera: OR light attachment (surgical field) 2 1 yes yes ___ ___ ___ ___ ___ ___ optional
5134 Clock: slave, dual theatre/ elapsed time 1 1 yes ___ ___ ___ ___ ___ ___ ___ master clock system
5980 Services pendant: 2 arm, height adj; 1a, 1b 1 1 yes yes ___ ___ ___ ___ ___ ___ 1x Anaesthetic services arm; 1x Surgical equipment arm
6468 Camera: in room 2 1 yes yes ___ ___ ___ ___ ___ ___ CCTV
6036 Electro-Surgical (Diathermy) Smoke Extractor 3 1 Yes ___ ___ ___ ___ ___ ___ ___
11400 Computer: PC & monitor 3 2 yes yes ___ ___ ___ ___ ___ ___ for nursing & medical staff
16000 Diathermy machine 3 1 yes ___ ___ ___ ___ ___ ___ ___
28301 Pump: infusion, single 3 1 yes ___ ___ ___ ___ ___ ___ ___ Qty TBC by project
36670 Operating table: mobile, electric 3 1 yes ___ ___ ___ ___ ___ ___ ___
39530 Patient warming device 3 1 yes ___ ___ ___ ___ ___ ___ ___ Type TBC by project
53850 Pump: syringe 3 1 yes ___ ___ ___ ___ ___ ___ ___ Qty TBC by project
54520 Telephone: handset, handsfree 3 1 ___ yes ___ ___ ___ ___ ___ ___ on wall
55750 Torniquet: surgical 3 1 yes ___ ___ ___ ___ ___ ___ ___ mobile
ID Description Service Category Qty Selection / Remarks
1006 Voice / Data outlet: double Communications 2 to documentation station; 1 outlet for telephone, optional
1007 Voice / Data outlet: triple Communications 3 to services pendants; 1-Anaesthetic arms-each, 1-Surgical arm
1012 Data outlet: single Communications 1 in room camera
1120 Monitor connection facilities and cabling Communications 1 to wall monitor, optional
1379 Audio/ Video outlet Communications 1 to documentation station, optional
1379 Audio/ Video outlet Communications 3 to services pendants; 1-Anaesthetic arms-each, 1-Surgical arm
1386 Voice / Data outlet: analogue telephone Communications 1 to documentation station; wall mounted
1922 GPO: Special: 20 amp Power to wall services panel 1; optional
1923 GPO: Special: 3 phase Power to wall services panel; optional
1947 Carbon Dioxide (CO2) Medical Gases 1 1 - Surgical pendant arm
1948 GPO: Single phase, high current, 32 Amp Power to wall services panel; for laser; optional
1951 Staff assist call Nurse Call 1 + indicator button & light; to wall services panel 2
2024 Music system Communications 1 optional
5005 Air conditioning: special HVAC HEPA filtered
5040 Pressure: positive HVAC
6001 General: colour corrected Lighting variable lighting level, dimmable
6074 Special: 'Laser In Use' lights Lighting outside room entries, if laser to be used (optional)
6200 Light switches Lighting light switches on service panel 1
7000 Oxygen (O2) Medical Gases 4 2-Anaesthetic pendant arms-each
7010 Nitrous Oxide (N2O) Medical Gases 2 1-Anaesthetic pendant arms-each
7020 Medical Air (MA) Medical Gases 2 1-Anaesthetic pendant arms-each
7030 Tool Air Medical Gases 1 1-Surgical pendant arm, with controls to wall
7040 Suction Medical Gases 6 2-Anaesthetic pendant arms-each, 2-Surgical pendant arm
7050 Gas Alarm Panel Medical Gases 1 wall mounted, to wall services panel 1
7062 Tool Air: unregulated Medical Gases 3 to services pendants; 1- each arm for pendant brakes
7070 Scavenge Medical Gases 2 1-Anaesthetic pendant arms-each
8080 Emergency call Nurse Call 1 + indicator button & light; to wall services panel 2
8090 Orderly/ Porter call Nurse Call 1 optional; to wall services panel 2
9000 GPO: Single Power 12 to services pendants; 4-Anaesthetic arms-each, 4-Surgical arm
9000 GPO: Single Power 2 to wall services panel 1
9000 GPO: Single Power 2 to wall services panel 2
9010 GPO: Emergency power, single Power 1 for LCD screen wall monitor, optional
9010 GPO: Emergency power, single Power 1 to wall services panel 2
9010 GPO: Emergency power, single Power 4 to wall services panel 1
9010 GPO: Emergency power, single Power 18 to services pendants; 6-Anaesthetic arms-each, 6-Surgical arm
9011 GPO: Emergency power, double Power 4 to documentation station
9014 GPO: UPS, double Power 2 to documentation station
9015 GPO: Cleaner Power 1 to wall
9050 Direct connection Power 5 1-clock, 2-pendants, 2-OR lights/flat panels
11000 Wall panel Services Panels 2 flush mounted, wall services
45570453 GPO: UPS, single Power 18 to services pendants; 6-Anaesthetic arms-each, 6-Surgical arm
9030 Cardiac protected/ IPS Power 1
0 0