Edit it in Health Facility Briefing System (HFBS) | |||
---|---|---|---|
![]() |
Edit this room data or print a PDF using the HFBS - Health Facility Briefing System. Customise this room data for your project, or add it to an existing health facility brief in HFBS Briefing Module. | Edit Briefing |
Room Layout Sheet | |||
---|---|---|---|
![]() |
Download a PDF Room Layout Sheet (RLS) for this standard component. | Free | View |
Other Files | |||
---|---|---|---|
![]() |
Buy an edible AutoCAD DWG Room Layout Sheet (RLS) for this standard component. | $2.99 |
Online Room Data Sheet |
---|
Room Code | OR-HY-CT-I |
Net Room Area Briefed | 70 |
Hours of Operation | 24 Hours |
Occupancy | 1 patient; 5 - 12 staff |
Description / Special Requirements | The Operating Room - Hybrid - CT provides an aseptic environment in which to carry out surgical procedures under local, regional or general anaesthetic. The room will adjoin the CT Scanning Room. The CT Gantry will move between the OR and the CT on floor tracks. The Operating Room - Hybrid is used for surgical procedures that require large and bulky equipment, including Neurosurgery. Cardiac Protected electrical area Special Air Conditioning - HEPA filtration Additional Design Considerations: - Minimum critical dimension 6000mm. - 'Laser In Use' warning lights may be required outside all exit doors to room if laser equipment is to be used - Lead shielding will be required; to be assessed by Radiation Consultant - External windows are desirable - double glazed with integral Venetian blinds - Provide isolated power supply individually to each large Operating Room, together with its associated line isolation and overload monitors |
Amendment | 24.10.10, - First Draft |
ID | Fabric | Material | Finish | Specification | Selection | Remarks |
7025 | Observation | Lead glass | Clear | Internal window | to Control Room | |
7001 | Windows | external windows desirable | ||||
2000 | Skirting | Vinyl | Prefinished | Floor vinyl coved, 150mmH | ||
3010 | Wall finish | Paint | Scrub resistant | |||
3038 | Wall finish | Vinyl | Prefinished | Wall vinyl to 900 AFFL | ||
5010 | Ceiling | Plasterboard | Paint, washable | Flush set, suspended | ||
8010 | Door protection | Composite | Prefinished PVC | Protection plate to 900 AFFL | Equal to 'Acrovyn' | |
8040 | Door protection | Composite | Prefinished PVC | To door frame | Equal to 'Acrovyn' | |
9232 | Doors | Solid Core/ Glass | Paint | Double leaf, with lead sheilding, lead glass observation panel | Clear opening to permit CT Gantry from adjoining CT room | |
9232 | Doors | Solid Core/ Glass | Paint | Double leaf, with lead sheilding, lead glass observation panel | 1800min clear opening to patient entry/ exit, sliding cover required | |
7026 | Observation | Lead Glass | Clear | Through door/s | with sliding cover | |
8001 | Door protection | Vinyl | Prefinished | To 900AFFL | ||
1000 | Floor finish | Vinyl | Standard slip resistant | Seamless, coved | ||
6015 | Cornice | Plasterboard | Paint | Flush coved between wall & ceiling |
ID | Description | Category | Group | Qty | Selection / Remarks |
150 | Air flowmeter | Furniture/ Fitting | 3 | 2 | to services on pendant |
300 | Trolley: anaesthetic | Furniture/ Fitting | 3 | 1 | |
1252 | Blind: Venetian integral | Furniture/ Fitting | 1 | 1 | to internal & external window, if provided |
1440 | Bowl stand: single | Furniture/ Fitting | 3 | 2 | |
1580 | Chair: anaesthetist | Furniture/ Fitting | 3 | 1 | |
6152 | Dispenser: disposable glove | Furniture/ Fitting | 2 | 1 | |
6410 | Documentation Station | Furniture/ Fitting | 2 | 1 | |
8390 | Trolley: gowns | Furniture/ Fitting | 3 | 1 | |
10200 | Trolley: instrument | Furniture/ Fitting | 3 | 3 | |
11100 | IV stand: mobile | Furniture/ Fitting | 3 | 2 | |
11500 | Kickbucket & stand | Furniture/ Fitting | 3 | 2 | |
12300 | Linen carrier: dirty, single | Furniture/ Fitting | 3 | 1 | |
13500 | Table: mayo | Furniture/ Fitting | 3 | 1 | |
16250 | Oxygen flowmeter | Furniture/ Fitting | 3 | 2 | to services on pendant |
21730 | Stool: operating, mobile | Furniture/ Fitting | 3 | 2 | |
21950 | Suction adapter | Furniture/ Fitting | 3 | 6 | to services on pendant; 2-low, 4-high |
22000 | Suction bottle | Furniture/ Fitting | 3 | 4 | in mobile carrier |
22050 | Suction bottle carrier | Furniture/ Fitting | 3 | 1 | |
24440 | Workstation: computer | Furniture/ Fitting | 2 | 1 | recessable |
ID | Description | Grp | Qty | Ele | Data | CdW | HtW | WmW | Tap | Dns | Gas | Selection / Remarks |
700 | Anaesthetic machine | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
1003 | Camera: PTZ | 2 | 5 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
9750 | Clock: slave, analogue | 1 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | master clock system |
9800 | Clock: time elapse | 1 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | beside analogue |
11400 | Computer: PC & monitor | 3 | 2 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | to Doc Station & Write-up Desk |
16000 | Diathermy machine | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
32605 | Light: operating, 2 arm 600d; with navigation panel | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
32651 | Light: operating, 1 arm; with dual flat panel | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
35950 | Monitor | 3 | 2 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | touch panel; part of Doc Station & Write-up Desk |
35960 | Monitor: anaesthetic | 3 | 1 | yes | opt | ___ | ___ | ___ | ___ | ___ | ___ | with printer, on anaesth machine |
36670 | Operating table: mobile, electric | 3 | 1 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | |
36240 | Monitor: flat panel | 2 | 1 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
47000 | Services pendant: ceiling | 3 | 2 | yes | yes | ___ | ___ | ___ | ___ | ___ | ___ | |
54520 | Telephone: handset, handsfree | 3 | 1 | ___ | yes | ___ | ___ | ___ | ___ | ___ | ___ | to workstation |
56800 | Television: large screen | 2 | 2 | yes | ___ | ___ | ___ | ___ | ___ | ___ | ___ | LCD screen; fitted & sealed to walls; reinforce wall to support up to 65kg weight |
ID | Description | Service Category | Qty | Selection / Remarks |
1006 | Voice / Data outlet: double | Communications | 1 | to wall adjacent to Write-up Desk; 1 outlet for telephone |
1017 | Hospital LAN | Communications | 2 | to services pendant |
1017 | Hospital LAN | Communications | 5 | to Doc Station & Write-up Desk |
1120 | Monitor connection facilities and cabling | Communications | to wall TV monitor | |
1379 | Audio/ Video outlet | Communications | 2 | to Doc Station & Write-up Desk |
1379 | Audio/ Video outlet | Communications | 4 | to services pendant |
1386 | Voice / Data outlet: analogue telephone | Communications | 1 | to Doc Station & Write-up Desk |
5005 | Air conditioning: special | HVAC | HEPA filtered | |
5040 | Pressure: positive | HVAC | ||
6001 | General: colour corrected | Lighting | variable lighting level, dimmable | |
6074 | Special: 'Laser In Use' lights | Lighting | outside room entries, if laser to be used | |
6076 | Special: 'X-ray In Use' lights | Lighting | 1 | outside room entries |
7000 | Oxygen (O2) | Medical Gases | 2 | to services pendant |
7010 | Nitrous Oxide (N2O) | Medical Gases | 1 | to services pendant |
7020 | Medical Air (MA) | Medical Gases | 2 | to services pendant |
7023 | Carbon Dioxide (CO2) | Medical Gases | 1 | to services pendant |
7030 | Tool Air | Medical Gases | 2 | to services pendant |
7040 | Suction | Medical Gases | 6 | to services pendant |
7050 | Gas Alarm Panel | Medical Gases | 1 | |
7060 | Tourniquet air | Medical Gases | 1 | and controls, to wall, optional |
7062 | Tool Air: unregulated | Medical Gases | 2 | to services pendant |
7070 | Scavenge | Medical Gases | 1 | to services pendant |
8010 | Staff/ Nurse assist call | Nurse Call | 1 | + indicator button & light |
8080 | Emergency call | Nurse Call | 1 | + indicator button & light |
8090 | Orderly/ Porter call | Nurse Call | 1 | |
9000 | GPO: Single | Power | 3 | to services panel |
9001 | GPO: Double | Power | 1 | to workstation |
9010 | GPO: Emergency power, single | Power | 12 | to services panels |
9010 | GPO: Emergency power, single | Power | 2 | for TV wall monitor |
9011 | GPO: Emergency power, double | Power | 7 | to services pendant |
9011 | GPO: Emergency power, double | Power | 9 | to Doc Station & Write-up Desk |
9014 | GPO: UPS, double | Power | 7 | to Doc Station & Write-up Desk |
9014 | GPO: UPS, double | Power | 7 | to services pendant |
9015 | GPO: Cleaner | Power | 1 | |
9016 | GPO: UPS, special | Power | 1 | 20 Amps; to services pendant |
9017 | Direct power (Essential Power), 10 amp | Power | 2 | to services pendant |
9022 | Isolated power supply system | Power | individually to each OR | |
9024 | Line isolation monitor | Power | to each OR | |
9026 | Overload monitor | Power | to each OR | |
9030 | Cardiac protected/ IPS | Power | ||
9050 | Direct connection | Power | 5 | for clocks & operating lights |
11000 | Wall panel | Services Panels | 5 |